Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

Reading a Centrifugal Pump Curve | Pumps & Systems

Reading a Centrifugal Pump Curve | Pumps & Systems

2 days ago · Basic Terms: Pump Curve, BEP, and System Curves A pump curve denotes flow on the x-axis (horizontal) and head pressure on the y-axis (vertical). The curve begins at the point of zero flow, or shutoff head, and gradually descends until it reaches the pump runout point or maximum flow rate.

Pump Performance - an overview | ScienceDirect Topics

Pump Performance - an overview | ScienceDirect Topics

Determine: Pump performance pumping 0.9 oil with viscosity 220 cSt (1000 SSU) Solution: (1) Determine the viscosity correction factors from Fig. 3.44 (1 of 2).. Enter Fig. 3.44 (1 of 2) with 750 gpm, 100 ft and 220 cSt (1000 SSU) and read the following correction factors:. Capacity correction factor (C Q): C Q = 0.95Head correction factor (C H): C H = 0.92

Vacuum pump pumping test- Vacuum Pump - EVP Vacuum .

Vacuum pump pumping test- Vacuum Pump - EVP Vacuum .

Any vacuum pump to be repaired, repaired vacuum pump or a new vacuum pump shall be tested to check whether there is any fault, the form and position of the fault, the limit vacuum degree that can be reached and the time that it has experienced. If there is any condition, it is necessary to identify the pumping rate. The specific methods and steps of test sampling are as follows:

Reading Industrial Pump Curves - C&B Equipment

Reading Industrial Pump Curves - C&B Equipment

2020-8-18 · Reading Industrial Pump Curves A properly sized industrial pump will operate efficiently for many years and can save a system from unexpected downtime, costs and wasted energy. Incorrectly sized pumps, on the other hand, can fail if they're too small or accrue unnecessary expense if too big.

Reading Industrial Pump Curves - C&B Equipment

Reading Industrial Pump Curves - C&B Equipment

2020-8-18 · Reading Industrial Pump Curves A properly sized industrial pump will operate efficiently for many years and can save a system from unexpected downtime, costs and wasted energy. Incorrectly sized pumps, on the other hand, can fail if they're too small or accrue unnecessary expense if too big.

How to Read a Pump Curve for Centrifugal Pumps | .

How to Read a Pump Curve for Centrifugal Pumps | .

Centrifugal Pump curves show 8 important factors that are critical in selecting the right pump for your application. These factors are: Flow, Head, Impeller Trim Diameter, Efficiency, Power, NPSHR, MCSF (Minimum Continuous Stable Flow) and RPM. The Pump curve also displays the Pump model, the Pump size and number of stages for multi-stage pumps.

How To Read A Centrifugal Pump Curve

How To Read A Centrifugal Pump Curve

2020-8-15 · If you are new to pumps and fluid processing, reading a pump curve can be a daunting, confusing task. Then, just when you think you understand curves, you realize that different types of pumps (centrifugal, positive displacement, air operated diaphragm.) have different types of curves .

Hayward Hydraulics and Pump Sizing For Existing Pools

Hayward Hydraulics and Pump Sizing For Existing Pools

2017-11-7 · A vacuum gauge can be used on the suction side of the system to provide a vacuum reading in inches of mercury. The pump's drain plug port that is closest to the front of the pump is an ideal place to attach the vacuum gauge. Take the vacuum reading of the pump and multiply the value by 1.13.

Understanding Vacuum and Vacuum Measurement

Understanding Vacuum and Vacuum Measurement

2019-5-9 · Low Vacuum – also called rough vacuum, is a vacuum that can be achieved or measured by basic equipment such as a vacuum cleaner. Medium Vacuum – is a vacuum that is typically achieved by a single pump, but the pressure is too low to measure with a mechanical manometer. It can be measured with a McLeod gauge, thermal gauge, or a capacitance .

Rotary Vane Vacuum Pumps & Systems | VACUUM WORLD .

Rotary Vane Vacuum Pumps & Systems | VACUUM WORLD .

VACUUM WORLD offers rotary vane vacuum pumps and packages on tanks and skids from Powerex, Dekker, Travaini, Becker and all of the major vacuum suppliers.

How to get a pump curve quickly | Grundfos

How to get a pump curve quickly | Grundfos

2 days ago · When reading pump curves, simply type in your duty point or just click directly on the graph and compare it to the pump curve. You can also do quick calculations on efficiency, speed and P1. Step 3: Print pump curve and additional data.

READING FIRE PUMP FACTORY PERFORMANCE CURVES

READING FIRE PUMP FACTORY PERFORMANCE CURVES

2015-4-11 · READING FIRE PUMP FACTORY PERFORMANCE CURVES Published on April 11, 2015 April 11, . is what can cause low discharge pressure readings and pumps pulling a vacuum on the suction at the higher .

The 'Absolute' Best Way to Monitor Your Pumping System's .

The 'Absolute' Best Way to Monitor Your Pumping System's .

If the pump is tested with a different liquid, or at a different temperature, it will be stated on the pump curve. If water converts into a gas inside the pump, either as steam (high temperature) or vapor (low pressure), the pump will not work. The NPSHr test determines the pump's low-pressure (vacuum) limits to deal with this gas.

Frequently Asked Questions | US Vacuum Pumps

Frequently Asked Questions | US Vacuum Pumps

Many vacuum pump performance curves shows ACFM to indicate the actual volume of process gas pumped at various inlet pressure to the pump. What is an Absolute vacuum gauge? An absolute pressure gauge is one that will measure your vacuum system without regard to and independent of local barometric pressure.

Guide to Reading a Positive Displacement Pump Curve .

Guide to Reading a Positive Displacement Pump Curve .

2020-8-18 · Positive displacement (PD) pump technologies vary, as do the curves for these pumps. A person without significant exposure to pump selection is often experienced only with centrifugal pump curves. Therefore, it can be frustrating to get the data required from a positive displacement curve.

Pumps 101 | Intro to Pumps

Pumps 101 | Intro to Pumps

Once you've been in the pump industry a while, reading a pump curve will be second nature. However, if you've never been taught how to read and understand a pump curve, it's a skill you must master as quickly as possible. This quick guide will have you reading pump curves in just a few minutes.

How to Read a Pump Curve from Cole-Parmer

How to Read a Pump Curve from Cole-Parmer

2018-11-19 · Cole-Parmer makes every attempt to publish a representative flow versus back pressure curve. In many cases, we can also furnish performance curves that quantify parameters such as NPSH req.. NPSH req: The Net Positive Suction Head that must be available to the pump for cavitation-free operation. NPSH req is typically expressed in either foot of head or units of pressure.

Top 8 Vacuum Pumps of 2019 | Video Review

Top 8 Vacuum Pumps of 2019 | Video Review

The suction pump was the precursor of the vacuum pump and is responsible for prompting the research that led to its development. The invention of the suction pump dates all the way back to the ancient city of Pompeii, which was founded in in the sixth or seventh century B.C. Suction pumps were also used in Arabia in the 13th century and later .

How to Read a Positive Displacement Pump Curve - Intro to .

How to Read a Positive Displacement Pump Curve - Intro to .

While pump curves help you select the right pump for the job, you first have to know the total dynamic head for the application. Total Dynamic Head (TDH) is the amount of head or PSI of pressure on the suction side of the pump (also called static lift), plus the total of 1) height that a fluid is to be pumped plus 2) friction loss caused by .

How to Read a Pump Curve | Intro to Pumps

How to Read a Pump Curve | Intro to Pumps

2018-12-13 · It is therefore used in pump performance testing to ensure that the pump actually performs as guaranteed by the manufacturer via the pump curves. Reading a pump performance curve In the simplest words, pump performance curve is a graph of 'differential head' developed by the pump, plotted against the operating flow rate.

Reading Centrifugal Pump Curves

Reading Centrifugal Pump Curves

2016-2-5 · Reading and understanding centrifugal pump curves is key to proper pump selection, and to their reliable and efficient operation. This Tech Brief examines how pump curves can provide data about a pump's abili-ty to produce flow against certain head, shows how to read a typical centrifugal pump curve, and provides information about pump .

Pressure Measurement - Gamma Vacuum

Pressure Measurement - Gamma Vacuum

Amps = Current reading in Amps Number of Elements = 25L: N = 1, 60: N = 2, 120: N = 4, 220: N = 8. Individual Curves. Individual pump current vs. pressure curves are still available for Ultek, Perkin Elmer, and PHI ion pumps. Please contact Gamma Vacuum for availability.

Pump Sizing and Selection Made Easy - Chemical .

Pump Sizing and Selection Made Easy - Chemical .

Power consumption increases rapidly with a viscosity increase because of reduced efficiency. In order to select a pump from standard performance curves, it is necessary to apply correction factors to determine the equivalent pumping rate and total dynamic head for water before reading the pump curves.

Pressure Measurement - Gamma Vacuum

Pressure Measurement - Gamma Vacuum

Amps = Current reading in Amps Number of Elements = 25L: N = 1, 60: N = 2, 120: N = 4, 220: N = 8. Individual Curves. Individual pump current vs. pressure curves are still available for Ultek, Perkin Elmer, and PHI ion pumps. Please contact Gamma Vacuum for availability.

Power Consumption of a Liquid Ring Vacuum Pump

Power Consumption of a Liquid Ring Vacuum Pump

The curves supplied for the pumps are for operation of the pump with air pulled into the inlet through one or many orifices thus restricting the flow and creating the vacuum. The standard is air at a temperature of 60 degrees Fahrenheit, 50% relative humidity, 29.92"Hg atmospheric pressure, with 60 degree cooling water and no backpressure on .

Power Consumption of a Liquid Ring Vacuum Pump

Power Consumption of a Liquid Ring Vacuum Pump

The curves supplied for the pumps are for operation of the pump with air pulled into the inlet through one or many orifices thus restricting the flow and creating the vacuum. The standard is air at a temperature of 60 degrees Fahrenheit, 50% relative humidity, 29.92"Hg atmospheric pressure, with 60 degree cooling water and no backpressure on .

How to Read Pump Curves & What They Mean

How to Read Pump Curves & What They Mean

How to Read Pump Curves & What They Mean Contributed by Zoeller Engineering Department The key thing to remember when reading a pump curve is all curves are based upon the principle of plotting data using the x and y axis. With this in mind, the curves typically plotted are head vs. capacity, power input vs capacity, and pump efficiency vs .

Lecture 2 notes

Lecture 2 notes

2015-10-8 · Anatomy of an IRMS Lecture 2 – Vacuum Pumps 1 Optional Reading: "Creating a Vacuum", "Pump down curves", and "Pumping speed in drydown zone". 1) Introduction a) What is a vacuum? i) A little tricky to define. "No air" is not technically correct.

Hayward Hydraulics and Pump Sizing For Existing Pools

Hayward Hydraulics and Pump Sizing For Existing Pools

2017-11-7 · A vacuum gauge can be used on the suction side of the system to provide a vacuum reading in inches of mercury. The pump's drain plug port that is closest to the front of the pump is an ideal place to attach the vacuum gauge. Take the vacuum reading of the pump and multiply the value by 1.13.

Dry ROTARY VANE Vacuum Pumps

Dry ROTARY VANE Vacuum Pumps

2019-4-5 · A 0-30"Hg vacuum gauge comes standard with all DV vacuum pump models DV-10, 17, 25 & 50. The gauge is referenced to local barometric pressure, thus variability of maximum vacuum reading will occur from day to day. Inlet Piping Inlet piping should be at least the size of the pump inlet.