Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

Series

Series "R" Reactors O-Ring Closure | High Pressure Company

The Series "R" O-ring Closure Reactors are easily assembled and disassembled with minimal torque required for complete engagement. Material of construction for standard models is Type 4340 alloy steel (or equivalent) properly heat treated for use at elevated pressures.

Aspen HYSYS Dynamic Modeling - ???????? - FUMcpanel

Aspen HYSYS Dynamic Modeling - ???????? - FUMcpanel

2016-11-14 · This manual is intended as a guide to using AspenTech's software. This documentation contains AspenTech proprietary and confidential information and may not be disclosed, used, or copied without the prior consent of AspenTech or as set forth in the .

NR-1000 Low Pressure Reactor - NR-series Reactors .

NR-1000 Low Pressure Reactor - NR-series Reactors .

The usable volume of the reactor can be varied between 500ml, 1,000ml and 2,000 ml using different reactor vessels. The NR-500/1000/2000 low-pressure reactor is notable for its ease of handling. The reactor is closed using a manual quick closure that can be attached without the use of tools.

2.0 Reactor Core & Vessel Design__

2.0 Reactor Core & Vessel Design__

2010-10-22 · Reactor Core & Vessel Design Chapter 2.0 Westinghouse AP1000 Technology Manual Safety Through Knowledge. Reactor Vessel 1. Reactor vessel is a modified three-loop Westinghouse reactor vessel. because of two SGs with four RCP loop design, direct vessel injection nozzles, and .

Mono (reactor-core 3.3.9.RELEASE)

Mono (reactor-core 3.3.9.RELEASE)

2020-8-10 · Subscribe to this Mono and block until a next signal is received, the Mono completes empty or a timeout expires. Returns an Optional for the first two cases, which can be used to replace the empty case with an Exception via Optional.orElseThrow(Supplier).In case the Mono itself errors, the original exception is thrown (wrapped in a RuntimeException if it was a checked exception).

5.1.6 Thermal-stress analysis of a reactor pressure vessel .

5.1.6 Thermal-stress analysis of a reactor pressure vessel .

To complete the closure assembly, an omega seal is welded to the under surface of the closure head and top surface of the vessel shell. The stud bolt is 2290 mm (90 in) in length and has a diameter of 146 mm (5.75 in). The closure nuts are 304 mm (12 in) long with a thickness of 28.6 mm (1.13 in).

Pressurized Water Reactor (PWR) Systems - SAnToS Lab

Pressurized Water Reactor (PWR) Systems - SAnToS Lab

2015-9-15 · reactor concepts manual pressurized water reactor systems usnrc technical training center 4-10 0603 rod travel housing instrumentation ports thermal sleeve lifting lug closure head assembly hold-down spring control rod guide tube control rod drive shaft inlet nozzle control rod cluster (withdrawn) access port reactor vessel lower core plate .

PWR Description - MIT OpenCourseWare

PWR Description - MIT OpenCourseWare

2020-7-10 · TYPICAL 4-LOOP REACTOR VESSEL. PARAMETERS. Overall length of assembled vessel, closure head, and nozzles 13.36 m InsidediameterofshellInside diameter of shell 439m4.39 m Radius from center of vessel to nozzle face Inlet Ol 3.33 m Outlet 3123.12 m Nominal cladding thickness 5.56 mm Minimum cladding thickness 3.18 mm

RELAP-7 Theory Manual - MOOSE

RELAP-7 Theory Manual - MOOSE

2017-1-31 · RELAP-7 is a new project started in Fiscal Year 2012. It will become the main reactor systems simulation toolkit for the LWRS (Light Water Reactor Sustainability) program's RISMC (Risk Informed Safety Margin Characterization) effort and the next generation tool in the RELAP reactor safety/systems analysis application series. The key to the .

The Design Characteristics of Advanced Power Reactor 1400

The Design Characteristics of Advanced Power Reactor 1400

2010-10-15 · The reactor vessel is composed of a vertically mounted cylindrical vessel with a hemispherical lower head welded to the vessel and a removable hemispherical closure head. The major design improvements incorporated in the reactor vessel .

Bolted Closure Reactors | High Pressure Company

Bolted Closure Reactors | High Pressure Company

The Bolted Closure Reactors are designed for use up to 650°F (343°C) at the working pressures indicated. Standard material for the body, cover and gasket is Type 316 stainless steel. Standard O-rings may be used in place of the metal gasket when temperatures permit.

VVER1000 Simulator | IAEA

VVER1000 Simulator | IAEA

2020-8-10 · The VVER1000 simulator was originally developed by Moscow Engineering and Physics Institute for personnel training. It is executed on a personal computer in real time and provides a dynamic response with sufficient fidelity. This version of a simulator is highly suitable for educational and information purposes. The VVER simulator operational specifics are listed as follows:

High Temperature, Bolted Closure Laboratory Batch Reactors .

High Temperature, Bolted Closure Laboratory Batch Reactors .

2020-3-2 · The Parker Autoclave Engineers' Bolted Closure Reactor has been designed for reliable high pressure operation. The seal is a metal gasket machined from the same material as the vessel. Many combinations of standard components are available. The cover of the unit remains fixed in the stand to permit opening of the vessel without disassembling any process connections.

BWR Training Manual – Boiling Water Reactor Simulation

BWR Training Manual – Boiling Water Reactor Simulation

Plant Transient Demonstrations - Manual Reactor Scram, High Reactor Vessel Pressure Scram, Low Reactor Vessel Water Level Scram, High Reactor Power Scram, Reactor Feed Pump Trip and Recirculation Runback, Turbine Generator Trip, Main Steam Isolation Valve Closure.

o-ring closure reactors

o-ring closure reactors

HiP BC Series Bolted Closure Reactors - Kinequip, Inc. HiP R Series Reactor O-Ring Closure (one piece cover) Quick View HiP R Series Reactor O-Ring Closure (one piece cover) HiP Pressure Vessel Reactors / R Series / One Piece Cover Maximum Working PSI Pressure ranges from 10,000 up to 150,000 psi service rating Connection Location: One Connections (top cover) 1/4" tubing .

Pressurized Water Reactor B&W Technology .

Pressurized Water Reactor B&W Technology .

2012-12-5 · The reactor vessel consists of a cylindrical shell, a spherically dished bottom head, and a ring flange to which a removable closure head is bolted. The closure head is a spherically dished head welded to a ring flange, which mates with and is bolted to the vessel ring flange with large-diameter studs. Two concentric metallic O-rings provide

RELAP-7 Theory Manual

RELAP-7 Theory Manual

2015-5-5 · ential Equations) and experimental based closure models. RELAP-7 utilizes well-posed governing equations for compressible two-phase flow, which can be strictly verified in a modern verification and validation effort. Closure models used in RELAP5 and newly developed models will be reviewed and selected to reflect the progress made during the

Maintenance and Repair of Glass-Lined Equipment

Maintenance and Repair of Glass-Lined Equipment

A customized inspection and maintenance program will minimize operational and performance problems with glass-lined equipment. Glass-lined steel equipment is used in a wide range of chemical processes that involve harsh chemicals, including the production of pharmaceuticals, specialty chemicals, agricultural products and polymers.

Parr Instrument Company Stirred Reactors and Pressure .

Parr Instrument Company Stirred Reactors and Pressure .

2018-10-17 · Parr Instrument Company 25 1-800-872-7720 Stirred Reactors 2 Series No. Reactor Type Nominal Size Maximum Pressure psi (bar) Maximum Temperature °C 4520 Mid-Size, Bench Top 1000 and 2000 mL 1900 (131) 225-350 4520 HP Mid-Size, Bench Top, High Pressure 970 and 1900 mL 2900 (200) 350 4530 Mid-Size, Moveable Cart or Floor Stand 1000 and 2000 mL 1900 (131) 225-350 .

Manual Closure Reactor, Capacity: 2-3 KL, Rs 1600000 .

Manual Closure Reactor, Capacity: 2-3 KL, Rs 1600000 .

Orbit Research Associates Private Limited - Offering Manual Closure Reactor, Capacity: 2-3 KL at Rs 1600000/piece in New Delhi, Delhi. Read about company. Get contact details and address | .

Split-Ring Closures - Parr Instrument Company

Split-Ring Closures - Parr Instrument Company

2 days ago · Parr reactors and pressure vessels are equipped with a unique split-ring cover clamp which adds greatly to the convenience of the equipment and the ease with which it can be handled. This is an exclusive Parr design (Split-Ring U.S. Patent No. 2625296) which allows easy access to a pressure vessel without using a heavy screw cap, cumbersome cover clamps, or a wide flange for moveable bolts.

Reactor vessel stud turnout tool - Westinghouse Electric Corp.

Reactor vessel stud turnout tool - Westinghouse Electric Corp.

1980-9-23 · A closure head is located on the top of the reactor vessel and is usually bolted thereto by a plurality of studs that extend through the closure head and into the reactor vessel so as to seal the radioactive material in the reactor vessel.

Biostat STR® Generation 3 Single-Use Bioreactor | Sartorius

Biostat STR® Generation 3 Single-Use Bioreactor | Sartorius

Biostat STR® is engineered for highly efficient mixing and high oxygen transfer. In addition to the standard features, you can incorporate advanced options such as an integrated spectroscopy port, Repligen's XCell™ ATF cell retention device, BioPAT® process control tools and software, and sophisticated analytics.

Mono (reactor-core 3.3.9.RELEASE)

Mono (reactor-core 3.3.9.RELEASE)

2020-8-10 · Subscribe to this Mono and block until a next signal is received, the Mono completes empty or a timeout expires. Returns an Optional for the first two cases, which can be used to replace the empty case with an Exception via Optional.orElseThrow(Supplier).In case the Mono itself errors, the original exception is thrown (wrapped in a RuntimeException if it was a checked exception).

Reactor Accessories | Pfaudler

Reactor Accessories | Pfaudler

The manway cover system closes and opens the largest flanged connection of a reactor. Our closure system ensures safe, easy operation. Our Fillook and Glasslook handhole covers with fused leak-free sight glasses are the safest solution for viewing reactor contents. The cover can be provided with up to four ports to free up reactor top head nozzle.

Instr Manual: M150 Gas Reactor Column - en - REMRSEC .

Instr Manual: M150 Gas Reactor Column - en - REMRSEC .

Instruction Manual. M150 Gas Reactor Column. Manor Royal, Crawley, West Sussex, RH10 2LW, UK. Telephone: +44 (0) 1293 528844 Fax: +44 (0) 1293 533453. . Figure 5-1 - Disconnect the heater unit from the enclosure. M150 Gas Reactor Column 5-5. 1. Thermocouple connectors on cartridge. 2. Thermocouple connectors on heater unit extension leads. 3 .

Maintenance and Repair of Glass-Lined Equipment

Maintenance and Repair of Glass-Lined Equipment

A customized inspection and maintenance program will minimize operational and performance problems with glass-lined equipment. Glass-lined steel equipment is used in a wide range of chemical processes that involve harsh chemicals, including the production of pharmaceuticals, specialty chemicals, agricultural products and polymers.

Fermentation & Bioreactors | Sartorius

Fermentation & Bioreactors | Sartorius

Discover the broadest selection of bioreactors & fermenters in the industry. Scalable from 8 mL up to 2,000 L, single-use or made from stainless steel!

Surface tension measurement services,Surface Tensiometer .

Surface tension measurement services,Surface Tensiometer .

Manual Closure Reactor. Manual Closure Reactor TOP 45 to TOP 160 Volume: 20 ml . Combinational Chemistry. A rapid parallel multi-reactor station under diverse gases for num. Slow Strain Rate Test (SSRT) o. 220 bar / 360 ° C Any type of corrosion standard samples:.

Bolted Closure

Bolted Closure

2016-8-29 · 1000 ml Bolted Closure Reactor Internals Bolted Closure Stirred Reactors: 500 and 1,000 ml ** Overall height based on belt driven units. Consult factory for overall height of other configurations. Note The user should be aware that the 650ºF (343ºC) vessel temperature rating is the maximum mean wall temperature of the